INTRODUCTION

DRY COOLING TOWER is an equipment which is used to cool and maintain the temperature of process hot water at a particular level. This operates on the principle of heat transfer by a heat exchanger with extends fins. The fan is driven by an Electric motor.

TECHNICAL SPECIFICATIONS

Copper Tubes:  The best quality imported (5/8") copper tubes in Level Wound Coils are used. This ensure coils with the minimum number of joints by forming a hair pin bends as well as to form a uniform wall thickness that eliminates embarrassing and expensive leaks after installation. Tubes are staggered in the path of airflow for better heat transfer efficiency.

Return Bends : They are die-formed from thick walled tubing that is heavier than the standard tubing used in the rest of coils. This provides the toughness and durability required in the most vital parts of the coil.

Headers : Inlet and outlet headers are constructed of heavy wall steel pipes with shoulders formed at each brazed connection to the 5/8" tube in the coil. This shoulders intruded with specially tooling provides the strength to the brazed joint that eliminates another source of leak during transit and installation.

Mechanical Tube Expansion : Tubes are Mechanically expanded for an optimum bond between tube and fin. This positive and controlled expansion procedure provides a clean, smooth inner tube surface for allow water pressure drop and guarantees uniform heat transfer between tubes.

Heat Transfer Coils

Improved Circuiting : The GEM Cooling Tower Design of water circuiting provides flexibility in selection and unequaled performance optimization. All inlet and outlet connections are provided on the same end thus reducing expensive piping and installation costs.

Rigid Construction : A die formed galvanized steel frame provides stacking and shipping support and protection against tube damage during expansion and installation.

Venting, Draining and Expansion Tank : Each water duty coil is provided with a convenient vent connection at the highest point and a drain connection at the lowest point apart from a small expansion tank.

Pressure Testing : Each coil is pressure tested after manufacture, by air under water at 300psi for water application.

Computerized Selection : Speeds up and simplify the selection of right coil for your specific requirements.

BACK   

(TOP)   

Automotive Tools Div. | Industrial Tools Div. | Electrical Tools Div. | Mining & Construction Tools Div. |

Lubrication Tools Div. | Material Handling Tools Div. | Dryers and Cooling Towers | Mechanical Tools Div. |

Compressors | Painting Tools Div. | Measuring Tools Div. | Industrial Adhesives | Instrument Products |